XH-W1401 Intelligent Digital Temperature Controller Upper and Lower Limit Setting 3 Windows Synchronous Display

XH-W1401 Intelligent Digital Temperature Controller Upper and Lower Limit Setting 3 Windows Synchronous DisplayItem NO.: XH-W1401

US$ 6.89
Quantity
1Pcs
10Pcs
100Pcs
1000Pcs
5000Pcs
Customized Requirements
Quantity
Adding to cart succeed
XH-W1401 Intelligent Digital Temperature Controller Upper and Lower Limit Setting 3 Windows Synchronous Display
color:red,size:xxl
Subtotal: US$ 0
View My Cart

Copy and share this link on social network or send it to your friends

Copy
  • XH-W1401 Intelligent Digital Temperature Controller

     

    1、High temperature start - cooling mode:

     

    When the starting temperature value is greater than the stopping temperature value, and the detection temperature is greater than or equal to the starting temperature, the relay will close and the refrigeration equipment will work; When the detection temperature is ≤ the stop temperature, the relay is disconnected and the refrigeration equipment stops working. For example, set the start temperature to 30 ℃ and the stop temperature to 25 ℃. When the detection temperature value is ≥ 30 ℃, the relay will close and the start indicator light (red) will light up; When the detected temperature value is ≤ 25 ℃, the relay is disconnected and the stop indicator light (green) is on.

     

    2、Low temperature start heating mode:

     

    When the starting temperature value is less than the stopping temperature value, and the detection temperature is less than or equal to the starting temperature, the relay will close and the heating equipment will work; When the detection temperature is ≥ the stop temperature, the relay is disconnected and the heating equipment stops working. For example, set the start temperature to 25 ℃ and the stop temperature to 30 ℃. When the detected temperature value is ≤ 25 ℃, the relay will close and the start indicator light (red) will light up; When the detected temperature value is ≥ 30 ℃, the relay is disconnected and the stop indicator light (green) is on.


Contact Us

Email:auto@i-emind.com

WhatsAPP:+86 15359446863

Wechat:+86 15359446863

Tel:+86 15359446863


Company Info
About Us
User Center
Forget Password My Orders Tracking Order My Account Register
Payment & Shipping
Locations We Ship To Shipping Methods Payment Methods
Company Policies
Return Policy Privacy Policy Terms of Use